37
Turn off the fuel pump.
Turn off the main fuel supply valve (see figure 20) and the control
desk fuel control knob.
Turn off the water supply to the apparatus by turning the main water
supply valve OFF.
Before leaving the lab, ensure that there are no objects left on the
apparatus. Clean the apparatus with a piece of cloth.
4.4.3 Emergency Shutdown
Follow the following procedure in given order to shut down the gas turbine
apparatus in case of emergency:
1. Shut off the fuel burner (atomizer) by turning the fuel operating lever.
2. Move the control desk throttle lever to shut off position.
3. Turn off the fuel pump.
4. Turn off the main fuel supply valve (see figure 20) and the control
desk fuel control knob.
5. Turn off the water supply to the apparatus by turning the main water
supply valve OFF.
6. Remove the dynamometer load and ensure there is no load on the
engine.
7. Before leaving the lab, ensure that there are no objects left on the
apparatus. Clean the apparatus with a piece of cloth.
8. Notify instructor of any problems or reasons that the experiment was
terminated.
5.0 Inspection
Inspections at regular intervals shall be performed on the apparatus to ensure
that the apparatus is kept in a safe and well maintained condition. The
inspection includes the observation of any cracks in main fuel tank, control
desk fuel tank, fuel & water pipe line, leaks in combustion chamber and
engine exhaust and a routine check for bare & cut electrical wires in the
apparatus.